Bakersfield will thrive again! Moderated business marketplace list   >   Venola   >   Maintenance and Repair   >   Agilent - hp 5518A laser head / receiver

Agilent - hp 5518A laser head / receiver


The Agilent 5518A laser head, used in Agilent interferometer systems, is similar in function to the more recently introduced Agilent 5519A Laser Head. It includes an internal measurement receiver, but it requires an external power supply. The Agilent 5518A is used primarily as the laser source in Agilent 5528A Laser Measurement system. It can also be used in place of an Agilent 5519A Laser Head when upgrading an Agilent 5528A system to an Agilent 5529A Dynamic Calibrator. The Agilent 5518A has a laser beam diameter of 6 mm, and offers a vacuum wavelength accuracy of ±0.1 ppm. The laser head uses a proven long-life laser tube with a demonstrated Mean Time Between Failure (MTBF) of greater than 50,000 hours of operation.
The Agilent 5518A is configured with appropriate optics and system electronics to build a laser interferometer system that meets the unique physical layout and measurement requirements of individual applications. The custom positioning system improves product quality, increases yields, and facilitates manufacture of precision products.
* Helium-neon, continuous wave, two-frequency laser
* Fast warm-up (typically four minutes)
* Internal measurement receiver
* Weight: 5.5 Kilograms (12 pounds)
* Magnetic Field Strength (Non-Operating): Does not exceed 5.25 milligauss at a distance of 460 cm (15 ft) from any point on the surface of the packaged Laser Head.
* Clearance Required for Cabling: 10.16 cm (4 in) beyond back
* Power Input Requirements: +15 Volts +/- -0.3 Volts at 25 Amperes maximum, -15 Volts +/-0.l3 Volts at 0.02 Ampere maximum
* Heat Dissipation: 23 watts during operation, 35 watts during warmup
* Maximum Beam Power Output: 1 milliwatt
* Minimum Beam Power Output: 180 microwatts
* Beam Diameter: 6 millimeters (0.25 inch) typical
* Vacuum Wavelength Accuracy (3 sigma, lifetime): 0.1 ppm
* Vacuum Wavelength Stability: Typical 1 hour: 0.002 ppm
* Typical lifetime: 0.02 ppm
* Nominal Vacuum Wavelength: 632.99137 nanometers
* Reference Frequency: 1.7 to 2.4 MHz for Agilent 5518As with serial number 2532A02139 and above, 1.5 to 2l.0 MHz for previous Agilent 5518As
* Industry-leading reliability
For any questions on pricing or availability please email or call:
For technical questions please email through this listing.



Agilent - hp 5518A laser head / receiver